Determining Microvolts Per Graduation

Determine the appropriate µV per graduation for your scale application.

Total load cell build.

Formula for Count By:
Count By = Scale Capacity / Graduations

Formula:

 mV/V *  Excitation * 1000 *  Count By(lb/kg)

(Total Load Cell Build)

= µV/Graduation

0 µV/graduation

This value should range from 1µV/graduation (or slightly less) to 30µV per graduation or more.  Note: Always consult your digital weight indicator's specifications for the appropriate uV/graduation compatible with your device.